DELTA COOLING TOWERS · DFC-60 UX & HUX Series

CTI Certified Cooling Towers

Delta’s DFC-60 UX & HUX Series is the CTI-certified version of Delta’s proven DFC-60 rectangular cooling tower range. Designed as an induced-draft counter-flow cooling tower, it combines a modular rectangular construction, durable FRP materials, and efficient cooling performance with independently verified thermal ratings under CTI STD-201.

Delta’s CTI certification has been in effect since 2018, reflecting consistent design, tested performance, and ongoing compliance with CTI’s certification requirements.

DELTA COOLING TOWERS · DFC-60 SERIES

Square & Rectangular Cooling Towers

A clear introduction to Delta’s square and rectangular cooling tower range, covering its intended applications and the factors that guide product selection.

CTI Certification

Independently Verified Thermal Performance

The DFC-60 UX & HUX Series is certified by the Cooling Technology Institute (CTI) under its CTI STD-201 thermal-performance certification programme. CTI certification provides independent, third-party assurance that a cooling tower line performs in accordance with the manufacturer’s published thermal ratings.

Under the CTI programme, either the purchased model or another model within the same certified product line is tested by a CTI-licensed testing agency. Certification is maintained through ongoing verification, helping ensure that published performance claims reflect actual operating performance.

CTI Certification Validation Number: C85A-18R01

Why CTI Certification Matters

  • Confirms thermal performance against published ratings.
  • Provides independent, third-party validation.
  • Supports confident selection for critical and duty-intensive applications.
  • Requires successful annual reverification to remain in effect.

 

CTI Certification

Independently Verified Thermal Performance

The DFC-60 UX Series is certified by the Cooling Technology Institute (CTI) under its CTI STD-201 thermal-performance certification programme. CTI certification provides independent, third-party assurance that a cooling tower line performs in accordance with the manufacturer’s published thermal ratings.

Under the CTI programme, either the purchased model or another model within the same certified product line is tested by a CTI-licensed testing agency. Certification is maintained through ongoing verification, helping ensure that published performance claims reflect actual operating performance.

CTI Certification Validation Number: C85A-18R01

Why CTI Certification Matters

  • Confirms thermal performance against published ratings.
  • Provides independent, third-party validation.
  • Supports confident selection for critical and duty-intensive applications.
  • Requires successful annual reverification to remain in effect.

 

Product Overview

Proven Design. Certified Performance.

The DFC-60 UX & HUX  Series retains the proven DFC-60 rectangular profile, modular construction, and induced-draft counter-flow cooling concept. Hot water is distributed evenly over high-efficiency fills, while the axial fan draws ambient air upward through the tower to remove heat through controlled evaporation.

Its rectangular form supports practical installation, easy maintenance access, and flexible layout planning in industrial sites, utility areas, and rooftop installations where dependable cooling performance is required.

KEY FEATURES

Certified Performance, Built for Reliability

CTI-certified thermal performance under CTI STD-201, independently verified against published ratings.

Rectangular modular design for practical installation, flexible layout, and convenient maintenance access.

High-strength FRP casing and basin for corrosion resistance, durability, and leak-proof operation.

Efficient water-distribution system for uniform water coverage across the fill pack.

High-efficiency PVC film fills for effective heat transfer between circulating water and air.

Top-mounted axial-flow fan with adjustable blade angle for efficient airflow and vertical discharge.

Efficient drift eliminators designed to reduce water carryover and minimize water loss.

Hot-dip galvanized structure, weatherproof motor, and durable internal components for long service life in demanding industrial conditions.

HOW IT WORKS

Distribute, Evaporate, Cool, Recirculate

STEP 01

Distribute

Hot water enters the tower and is distributed evenly across the fill pack through the water-distribution system.

STEP 02

Evaporate

As water flows downward through the high-efficiency fills, the induced-draft axial fan draws ambient air upward through the tower. The interaction between air and water causes a small portion of water to evaporate, removing heat from the circulating water.

STEP 03

Cool

Cooled water collects in the leak-proof FRP basin at the base of the tower. Drift eliminators help reduce water carryover while allowing air to discharge vertically.

STEP 04

Recirculate

Cooled water is recirculated from the basin back to the process, supporting continuous and reliable cooling operation.

TECHNICAL Highlights

Certified Cooling for Demanding Applications

Feature

DFC-60 UX Series

Tower type

Rectangular, induced-draft counter-flow cooling tower

Certification

CTI STD-201 thermal-performance certification

CTI validation number

C85A-18R01

Certification in effect since

2018

Construction

FRP casing, basin, and hot-dip galvanized structural/internal components

Water distribution

Efficient water-distribution system

Fill media

High-efficiency PVC film fills

Fan

Top-mounted axial-flow fan with adjustable blade angle

Drift control

Efficient drift eliminators

Installation suitability

Rectangular footprint; suitable for ground-level and rooftop installations where wind-load conditions are assessed

TECHNICAL Highlights

Certified Cooling for Demanding Applications

Tower type - Rectangular, induced-draft counter-flow cooling tower

Certification - CTI STD-201 thermal-performance certification

CTI validation number - C85A-18R01

Certification in effect since - 2018

Construction - FRP casing, basin, and hot-dip galvanized structural/internal components

Water distribution - Efficient water-distribution system

Fill media - High-efficiency PVC film fills

Fan - Top-mounted axial-flow fan with adjustable blade angle

Drift control - Efficient drift eliminators

Installation suitability - Rectangular footprint; suitable for ground-level and rooftop installations where wind-load conditions are assessed

APPLICATIONS

Certified Cooling for Critical Duty

The DFC-60 UX Series is suitable for recirculating water-cooling systems where verified thermal performance, dependable operation, and long-term reliability are priorities.

HVAC & Refrigeration

For compatible chiller-condenser water circuits, refrigeration plants, and utility cooling systems. Selection is based on equipment requirements and design operating conditions.

Process Industries

For circulating water systems that remove heat from process equipment and industrial operations. Selection considers process duty, operating temperatures, and water conditions.

Heat Exchangers

For water-cooling circuits serving heat exchangers and thermal-transfer equipment. Tower capacity is selected to match the specified heat-rejection duty.

Manufacturing Plants

For water-cooling systems supporting manufacturing equipment and production processes. Selection considers cooling duty, available space, and site operating conditions.

DFC-60 UX & HUX Series — Certified Performance You Can Trust

Delta’s DFC-60 UX & HUX  Series combines the proven DFC-60 rectangular design with independently verified CTI thermal performance.

Certified under CTI STD-201 since 2018, it is engineered for consistent cooling, durable construction, and dependable long-term operation.

Certified performance. Proven reliability. Built for critical cooling.

PRODUCT FAQs

Questions About the DFC-60 Series

Find answers to common questions about Delta’s rectangular and square FRP cooling towers, including their operation, configuration, applications, and selection requirements.

What information is needed to select a suitable cooling tower?
RELATED PRODUCTS

Explore Other Cooling Tower Solutions

ROUND COOLING TOWER

DFC-50

SQUARE COOLING TOWER

DFC-60

PULTRUDED FRP RANGE

DPC-70

Share your cooling requirement, BOQ, technical specification, or project details with our team. We will review your requirement and recommend a suitable cooling-tower solution.