DELTA COOLING TOWERS · DPX-80 SERIES

Pultruded FRP Induced-Draft Cross-Flow Cooling Towers

Delta’s DPX-80 Series comprises precisely designed, field-erected, induced-draft cross-flow cooling towers manufactured using high-strength pultruded FRP structural sections and durable FRP cladding. Engineered for large cooling capacities and demanding industrial environments, the series combines corrosion resistance, structural strength, efficient thermal performance, and flexible site-specific configuration.

 

The DPX-80 Series is designed for applications involving high flow rates and high heat rejection, including power generation, chemical processing, pharmaceuticals, food and beverage, cement, steel, and other heavy industries.

DELTA COOLING TOWERS · DFC-60 SERIES

Square & Rectangular Cooling Towers

A clear introduction to Delta’s square and rectangular cooling tower range, covering its intended applications and the factors that guide product selection.

PRODUCT OVERVIEW

Field-Erected Cooling for Large-Scale Duty

The DPX-80 Series is assembled at site using pultruded FRP structural sections, FRP casing and cladding, high-efficiency V-bars, low-drift eliminators, and an induced-draft axial fan system. This construction approach allows the tower to be configured around the project’s cooling duty, available footprint, water-flow requirements, and site constraints.

In a cross-flow cooling tower, hot water flows vertically downward through the fill while air enters from the sides and moves horizontally across the falling water. This cross-current arrangement provides a large air-water contact area, supports efficient heat transfer, and allows practical access to the fill and internal components for inspection and maintenance.

The tower structure is made from pultruded FRP sections, which provide high strength-to-weight performance, dimensional stability, and excellent resistance to corrosion, moisture, chemicals, and UV exposure. The FRP casing and cladding protect internal components from weather and industrial environments while keeping the structure lightweight and non-conductive.

KEY FEATURES

Engineered for Strength, Efficiency, and Long Service Life

Precisely designed field-erected construction for site-specific sizing, configuration, and installation flexibility.

Pultruded FRP structural sections and FRP casing/cladding for high strength, corrosion resistance, dimensional stability, and long-term durability.

Induced-draft cross-flow design for efficient heat transfer, with air entering from the sides and moving horizontally across vertically falling water.

High-efficiency V-bars supported on SS or GRP grids, designed to break water into fine droplets and maximise air-water contact for effective heat transfer.

Open gravity-type hot-water distribution basin with specialised nozzles, ensuring uniform water distribution across the fill area.

Low-resistance drift eliminators made from PVC extruded C-sections or other suitable profiles, designed to reduce drift losses and water carryover.

Multi-blade, adjustable-pitch axial FRP fans, available with direct-mounted CT-duty motors or gear-driven arrangements to suit project capacity, efficiency, and maintenance requirements.

Non-conductive pultruded FRP construction that is corrosion-resistant, electrically non-conductive, and suitable for demanding industrial environments, high temperatures, industrial shocks, environmental exposure, and heavy wind loads.

HOW IT WORKS

Distribute, Exchange, Evaporate, Recirculate

STEP 01

Distribute

Hot water coming from the industry is collected in the open gravity-type hot-water distribution basin located at the top of the tower. From this basin, water flows downward through specialised nozzles, where it is converted into fine droplets and distributed evenly over the V-bars.

STEP 02

Exchange

The fine water droplets fall onto high-efficiency V-bars, which are supported on SS or GRP grids. As the water travels downward through the fill area, ambient air enters from both sides of the tower and flows upward through the V-bars.

Water moves from top to bottom, while air moves from the sides upward. This creates a cross-current flow pattern, maximising the contact area and contact time between water and air for effective heat transfer.

STEP 03

Evaporate

As air and water interact, a small portion of water evaporates and removes heat from the circulating water. The fan mounted at the top of the tower is induced-draft type; it draws external air through the side inlets and discharges warm, humid air vertically from the top of the tower.

The fan may be directly mounted on a special cooling-tower-duty motor or driven through a gearbox, depending on the tower configuration and project requirements. The fan is a multi-blade, adjustable-pitch axial-flow type, allowing airflow optimisation for the required cooling duty.

STEP 04

Recirculate

Cooled water collects in the cold-water basin at the base of the tower and is recirculated back to the industry for reuse. Drift eliminators reduce water carryover while allowing air to discharge efficiently from the tower.

TECHNICAL Highlights

Built for Heavy Industrial Applications

Feature

DPC-70 Series

Tower type

Field-erected, induced-draft counter-flow cooling tower

Structure

Pultruded FRP sections with FRP casing and cladding

Fill media

Honeycomb, Trickle, Optigrid, or other low-fouling fills

Fill support

Pultruded square sections for high strength and reduced pressure drop

Water distribution

Specialised water-spray nozzles for uniform distribution across the fill area

Drift control

PVC extruded C-sections or other suitable drift-eliminator profiles

Fan system

Axial FRP fan with adjustable pitch

Drive system

Direct-driven or gear-driven arrangement, selected as per project requirements

Construction advantage

Reliable Cooling for Demanding Industries

TECHNICAL Highlights

Built for Heavy Industrial Applications

Final tower configuration, capacity, fill type, fan system, and materials should be confirmed against the project duty, water quality, site conditions, and applicable standards.

Tower type - Field-erected, induced-draft counter-flow cooling tower

Structure - Pultruded FRP sections with FRP casing and cladding

Fill media - High-efficiency V-bars supported on SS or GRP grids

Water distribution - Open gravity-type hot-water basin with specialised nozzles

Drift control - PVC extruded C-sections or other suitable drift-eliminator profiles

Fan system - Multi-blade, adjustable-pitch axial FRP fan

Drive system - Direct-mounted CT-duty motor or gear-driven arrangement

Airflow arrangement - Air enters from both sides and moves upward; water flows downward, creating cross-current contact

Construction advantage - Corrosion-resistant, electrically non-conductive, UV-resistant, and suitable for demanding environments

APPLICATIONS

Reliable Cooling for Demanding Industries

The DPX-80 Series is suitable for industrial facilities requiring dependable heat rejection, high cooling capacity, corrosion-resistant construction, and flexible field-erected installation.

Power Generation

For circulating water systems supporting power-plant cooling duties, condenser circuits, and high heat-rejection requirements. The series is engineered to handle high flow rates and demanding operating conditions.

Chemical & Petrochemical Plants

For cooling systems exposed to corrosive environments, process heat loads, and continuous industrial operation. Pultruded FRP construction supports long-term resistance to chemicals and environmental degradation.

Pharmaceutical & Food Processing

For hygienic and process-critical cooling applications where reliable temperature control and dependable operation are important. The series is suitable for pharmaceutical and food-and-beverage industries.

Cement, Steel & Heavy Industry

For large industrial cooling circuits serving manufacturing equipment, furnaces, process utilities, and high-heat-load operations. The DPX-80 Series is designed for heavy-duty, field-erected installations.

DPX-80 Series — Cross-Flow Cooling, Built to Endure

Delta’s DPX-80 Series brings together pultruded FRP strength, field-erected flexibility, and efficient cross-flow cooling for large-scale industrial applications.

Precisely designed for each project duty, it is built to resist corrosion, withstand demanding environments, and deliver dependable thermal performance with lower maintenance.

Field-erected strength. Efficient cross-flow cooling. Engineered to last.

PRODUCT FAQs

Questions About the DFC-60 Series

Find answers to common questions about Delta’s rectangular and square FRP cooling towers, including their operation, configuration, applications, and selection requirements.

What information is needed to select a suitable cooling tower?
RELATED PRODUCTS

Explore Other Cooling Tower Solutions

ROUND COOLING TOWER

DFC-50

CTI-CERTIFIED RANGE

DFC-60 UX & HUX

SQUARE COOLING TOWER

DFC-60

Share your cooling requirement, BOQ, technical specification, or project details with our team. We will review your requirement and recommend a suitable cooling-tower solution.