DELTA COOLING TOWERS · DFC-60 SERIES

Square & Rectangular Cooling Towers

Modular, induced-draft counterflow cooling towers engineered around your industrial water-cooling duty, operating conditions, and available installation space.

DELTA COOLING TOWERS · DFC-60 SERIES

Square & Rectangular Cooling Towers

A clear introduction to Delta’s square and rectangular cooling tower range, covering its intended applications and the factors that guide product selection.

PRODUCT OVERVIEW

Modular Cooling Towers. Application-Matched Solutions.

Delta’s DFC-60 Series comprises square and rectangular FRP cooling towers with an induced-draft counterflow design. Modular configurations allow the cooling-tower arrangement to be selected around your required thermal duty and available installation space.

From individual units to multi-cell arrangements, the series offers configuration flexibility for industrial water-cooling applications. Each selection considers circulating water flow, inlet and outlet temperatures, ambient conditions, and process requirements.

KEY FEATURES

Built for Reliable Industrial Cooling

Designed Around Your Cooling Duty

Modular Configurations

Square and rectangular configurations with multi-cell options help match cooling capacity and tower arrangement to your application and installation space.

Durable FRP Construction

Lightweight FRP casing and basin provide corrosion resistance and support long service life in suitable industrial operating environments.

Uniform Water Distribution

A static distribution system with PVC pipes, branch arms, and PP splash caps spreads circulating water across the fill area.

Induced-Draft Airflow

An axial-flow fan draws air upward through the tower, opposite to the downward water flow, supporting counterflow heat exchange.

Low Drift Water Losses

Drift eliminators capture entrained water droplets in the leaving airstream, helping maintain low water losses due to drift.

Application-Based Selection

Tower selection considers thermal duty, water quality, site conditions, and operating requirements to recommend a suitable configuration.

Aesthetic & Lightweight

UV-protected FRP construction with a smooth external finish offers a neat appearance and low weight. Rooftop installation is subject to structural approval and suitable site conditions.

Economical Maintenance

Readily available spare parts and compatibility with commonly used component designs support economical maintenance. Replacement parts must match the selected model’s specifications.

HOW IT WORKS

The Counter Flow Cooling Process

The DFC-60 Series cools recirculating process water through direct contact with air. Hot water moves downward through the fill while the induced-draft fan draws air upward. Evaporation of a small portion of the water removes heat from the remaining circulating water.

STEP 01

Distribute

Hot process water enters the distribution system and spreads across the fill through branch pipes and splash caps.

STEP 02

Evaporate

The fan draws air upward through the falling water. A small portion of the water evaporates, removing heat from the circulating water.

STEP 03

Cool

As evaporation removes heat, the remaining water cools while flowing down through the fill towards the collection basin.

STEP 04

Recirculate

Cooled water collects in the basin and is pumped back to the process for reuse in the circulating system.

TECHNICAL DETAILS

DFC-60 Series - Construction & Configuration

Review the principal construction and operating features of Delta’s square and rectangular FRP cooling towers.

Final construction, dimensions, motor rating, connections, and performance data depend on the selected model and specified duty conditions.

Parameter

Description

Series

DFC-60

Tower configuration

Square or rectangular; modular configurations

Operating principle

Induced-draft counterflow

Casing and basin

FRP construction

Water distribution

Static system with PVC pipes, branch arms, and PP splash caps

Fan system

Axial-flow fan; drive arrangement as specified for the selected model

Drift control

Drift eliminators to reduce entrained water-droplet carryover

Selection basis

Water flow, inlet and outlet temperatures, design wet-bulb temperature, water quality, and site requirements

TECHNICAL DETAILS

DFC-60 Series - Construction & Configuration

Review the principal construction and operating features of Delta’s square and rectangular FRP cooling towers.

Final construction, dimensions, motor rating, connections, and performance data depend on the selected model and specified duty conditions.

Series - DFC-60

Tower configuration -Square or rectangular; modular configurations

Operating principle - Induced-draft counterflow

Casing and basin - FRP construction

Water distribution - Static system with PVC pipes, branch arms, and PP splash caps

Fan system - Axial-flow fan; drive arrangement as specified for the selected model

Drift control - Drift eliminators to reduce entrained water-droplet carryover

Selection basis - Water flow, inlet and outlet temperatures, design wet-bulb temperature, water quality, and site requirements

APPLICATIONS

Industrial Water Cooling for Your Process

The DFC-60 Series can be selected for recirculating water-cooling systems in industrial and compatible HVAC applications. Suitability depends on the required cooling duty, water quality, operating conditions, and site arrangement.

Process Industries

For circulating water systems that remove heat from process equipment and heat exchangers. Selection considers process duty, operating temperatures, and water conditions.

Manufacturing Plants

For water-cooling circuits serving manufacturing equipment and production processes. Tower capacity is selected to match the equipment’s specified heat-rejection duty.

HVAC & Refrigeration

For compatible chiller-condenser water circuits and utility cooling systems, with selection based on the equipment requirements and design operating conditions.

Product Cooling & Quenching

For recirculating water systems supporting post-process product cooling, cooling baths, and compatible quenching applications. Selection considers cooling duty, water temperature, contamination levels, and process requirements.

DFC-60 Series — Engineered Around Your Process

Delta’s DFC-60 Series combines modular flexibility, durable FRP construction, and application-focused engineering for dependable industrial water cooling.
From individual units to multi-cell configurations, each solution is selected around your cooling duty, operating conditions, and available space.

Built for long service life. Designed for practical maintenance. Matched to your process.

PRODUCT FAQs

Questions About the DFC-60 Series

Find answers to common questions about Delta’s rectangular and square FRP cooling towers, including their operation, configuration, applications, and selection requirements.

What information is needed to select a suitable cooling tower?
RELATED PRODUCTS

Explore Other Cooling Tower Solutions

ROUND COOLING TOWER

DFC-50

CTI-CERTIFIED RANGE

DFC-60 UX & HUX

PULTRUDED FRP RANGE

DPC-70

Share your cooling requirement, BOQ, technical specification, or project details with our team. We will review your requirement and recommend a suitable cooling-tower solution.