Cooling Tower Spare Parts
Ready Availability. Reliable Performance.
Delta Cooling Towers maintains a ready stock of essential cooling-tower spare parts to help customers minimise downtime and restore tower performance quickly. From motors, fans, gearboxes, and drive shafts to fills, eliminators, nozzles, and structural components, Delta supplies spares for its own cooling towers as well as for other makes. Motors can be supplied with country-specific electrical characteristics, including phase, voltage, and frequency requirements.
Why Spare Parts Matter
Cooling-tower components operate continuously in a demanding environment of moisture, heat, airflow, and water-quality variation. Timely replacement of wear parts and critical components helps maintain heat-transfer performance, water distribution, fan efficiency, structural integrity, and reduced unplanned shutdowns.
Delta stocks every necessary spare readily available, including:
- Motors, fans, gear reducers, and drive shafts
- Fan stacks, cylinders, and fan decks
- Film fills, splash fills, and V-bars
- Drift eliminators and spray nozzles
- Sprinklers and water-distribution systems
- Pultruded FRP gratings, structures, tubes, angles, C-sections, I-sections, and claddings
Spare Parts Range
Cooling Tower Motors
Delta supplies special-duty cooling-tower motors designed for reliable operation in humid and corrosive tower environments.
- Direct-driven motors: TEAO, weather-proof, flange-mounted motors with extended shafts for direct fan mounting.
- Gear-driven motors: Standard TEFC, foot-mounted motors suitable for gearbox-driven cooling towers.
- Motors are sourced from reputed manufacturers with proven experience in cooling-tower applications.
- Motors can be supplied in country-specific configurations, including required phase, voltage, and frequency.
Cooling Tower Fans
Delta supplies special-duty cooling-tower motors designed for reliable operation in humid and corrosive tower environments.
- Direct-driven motors: TEAO, weather-proof, flange-mounted motors with extended shafts for direct fan mounting.
- Gear-driven motors: Standard TEFC, foot-mounted motors suitable for gearbox-driven cooling towers.
- Motors are sourced from reputed manufacturers with proven experience in cooling-tower applications.
- Motors can be supplied in country-specific configurations, including required phase, voltage, and frequency.
Gearboxes
Delta supplies gearboxes specifically designed and manufactured by reputed manufacturers for cooling-tower duty.
- Right-angle, oil-lubricated gearboxes reduce fan speed while transmitting the required torque.
- Speed reduction helps minimise noise, vibration, and mechanical wear.
- Gearboxes are engineered with an appropriate safety factor for demanding continuous operation.
- Suitable for motor-to-gearbox drive arrangements in gear-driven cooling towers.
Drive Shafts
Drive shafts transmit rotational power from the motor to the cooling-tower fan.
- Tubular, dynamically balanced construction for smooth and stable transmission.
- Supplied with flexible bushes, coupling elements, and yokes.
- Designed to accommodate alignment variation and reduce vibration.
- Suitable for motor-to-gearbox or gearbox-to-fan drive arrangements.
Fan Stacks / Cylinders
Fan stacks and cylinders provide a smooth passage for upward-moving air discharged from the cooling tower.
- Manufactured from heavy-duty FRP for durability and corrosion resistance.
- Help guide discharged air efficiently and reduce recirculation effects.
- Support consistent airflow through the tower, contributing to effective heat transfer.
- Available for replacement or upgrade in suitable cooling-tower models.
Film Fills
Film fills increase the contact area between downward-flowing hot water and upward-moving air, supporting efficient heat transfer.
- Vacuum-formed PVC fills with suitable angles and corrugations.
- Available in flute sizes such as 12 mm, 19 mm, and 25 mm.
- Designed to maximise water-film surface area within the cooling tower.
- Suitable for clean-water applications where high thermal performance is required.
Splash Fills
Splash fills are used where water quality is critical or where the water may contain suspended solids or fouling tendencies.
- Heavy-duty fill options include V-bars, loose polypropylene splash packs (LPS), trickle grids, and Optigrids.
- Designed for long service life and low fouling.
- Break water into droplets and create repeated contact with air for effective cooling.
- Suitable for applications where film fills may be prone to clogging.
Drift Eliminators
Drift eliminators reduce carryover of water droplets in the exhaust airstream, helping conserve water and limit drift losses.
- Available in S-type, honeycomb-type, blade-type extruded, V-type, and multi-wave configurations.
- Selected according to tower design, airflow, and application requirements.
- Help capture entrained water droplets and return them to the tower.
- Support water conservation and responsible cooling-tower operation.
Spray Nozzles
Spray nozzles distribute water uniformly over the fill or splash media, ensuring effective wetting and heat transfer.
- Heavy-duty nozzles available in PVC, PP, or brass.
- Designed to withstand elevated water temperatures and demanding operating conditions.
- Options include deck spray nozzles, target nozzles, spiral nozzles, and splash caps.
- Engineered for adequate spray coverage and uniform water distribution.
Sprinklers
Sprinklers are used in round bottle-type cooling towers to distribute water evenly across the fill area.
- Rotate automatically using the reaction force of the water flow.
- Help achieve uniform water distribution across the fill.
- The sprinkler assembly consists of one rotating head with four perforated branch pipes.
- Branch pipes distribute water evenly over the fill media below.
Fan Decks & FRP Sections
Delta supplies heavy-duty fan decks and pultruded FRP structural components for cooling-tower maintenance, repair, and upgrades.
- Anti-skid fan-deck sections for pultruded FRP cooling towers.
- Pultruded FRP tubes, angles, C-sections, I-sections, gratings, and claddings.
- Corrosion-resistant, lightweight, and high-strength structural components.
- Suitable for replacement, refurbishment, and modification of cooling-tower structures.
Spares Beyond Delta Towers
Delta can supply spare parts not only for Delta-manufactured cooling towers but also for cooling towers of other makes. Component selection is based on the tower model, dimensions, operating conditions, water quality, and existing installation details.
Motors can be supplied as per country-specific characteristics, including phase, voltage, and frequency.
Delta keeps essential cooling-tower spares ready—helping customers maintain performance, reduce downtime, and keep operations running.
Questions About the DFC-60 Series
Find answers to common questions about Delta’s rectangular and square FRP cooling towers, including their operation, configuration, applications, and selection requirements.
What information is needed to select a suitable cooling tower?
Which operating conditions should be considered?
What maintenance is required?
Can the cooling tower be configured for a specific site?
Explore Other Cooling Tower Solutions